■ For suppressing EMI
|
|
■ For suppressing common and differential
|
|
■ For mulit-mounting
methods
|
|
AC Power Noise Filter
|
|
|
★ Electrical Characteristics
|


|
|
▲ Rated voltage:
250Vac 380Vac(50HZ/60HZ)
|
|
▲ Rated current:
1A
、
2A
、
3A
、
6A
、
10A
|
|
▲ Withstand voltage:1500Vac
2300Vac
|
|
▲ Insulation resistance:≥
1G
Ω
|
|
▲ Attenuation characteristics:
≥30dB,≥40dB(1~30MHZ)
|
|
★ Environmental Characteristics
|
|
▲ Low temperature:
-25℃
,2h
|
|
▲ High temperature:
70℃
2h
|
|
▲ Vibration:10~55HZ,
50m
/s2,1h
|
|
▲ Shock:
300m
/s2,18ms,3次
|
|
△R≤±1%R,△(Uab/Uac)≤1%
|
|
▲ Temperature variation:
-25℃
,30min,+
85℃
,30min
|
|
5 cycles
|
|
▲ Constant damp-heat
|
|
GB2423.3,
Ca M
96h
|
|
(Subject to the above
tests, insulation
resistance, withstand voltage and
attenuation should meet the requirements
|
|
★
Physical Characteristics
|
|
▲ Mark
|
|
Type, withstand
voltage,
|
|
Rated voltage, Rated
current
|
|
▲ Connection
|
|
Terminal 1 and 2 to the power supply;
Termianl 3 and 4 to the equipment
|
|

|
|
Specification are subject to change without notice.
|