High power, high accuracy, small size |
■
Heat sink must be installed as
required when it's
used
|
|
RX24 Wire-Wound Resistor |
|
|
★
Standard
▲
Q/RU157-1999 Type RX24 Power Wire-Wound
Resistor specification
|


|
|

|
|
★
Dimension
|
|
Type
|
Body
sizes
|
Terminal
Dimension
|
|
L
|
W
|
HMAX
|
M1
|
M2
|
φD
|
L1
|
φD
|
|
RX24-5W
|
15.5
|
16.5
|
9
|
11.3±0.5
|
12.5±0.5
|
2.4
|
7±1.5
|
1.3
|
|
RX24-10W
|
19
|
20.5
|
10
|
14±0.5
|
16±0.5
|
2.2
|
8.6±1.5
|
2
|
|
RX24-20W(25W)
|
27
|
27.5
|
14
|
18±0.5
|
20±0.5
|
3.2
|
10.8±2
|
2
|
|
RX24-50W
|
50
|
29
|
15.5
|
40±0.5
|
22±0.5
|
3.2
|
10.8±2
|
2
|
|
|
★
Main Specification
|
|
Type
|
Resistance
range
(Ω)
|
Resistance
tolerance
±(%)
|
T.C.R.
±(×10-6/℃)
|
Limit
Voltage
(V)
|
Insulation
voltage
(V)
|
|
RX24-5W
|
0.511~3.32K
|
1(F)
2(G)
5(J)
R<10Ω
5(J)
|
100
≤10Ω
No stipulation
|
130
|
195
|
|
RX24-10W
|
0.511~4.42K
|
200
|
300
|
|
RX24-20W(25W)
|
0.511~8.66K
|
400
|
600
|
|
RX24-50W
|
0.511~26.1K
|
800
|
1200
|
|
|
★
Main Inspection items, methods & requirements
|
|
Items
|
Requirements
|
Methods
|
|
Terminal
strength
|
ΔR≤±(0.5%R+0.05Ω)
|
Tension
test 9.8N 10±1s
|
|
TCR
|
±100×10-6/℃(<10ΩNo
stipulation)
|
-55℃
/20
20/+
150℃
|
|
Constant
damp-heat
|
Insulation
resistance ≥10MΩ
ΔR≤≤±(1%R+0.05Ω)
|
40+
2℃
Relative humidity:93±3%
48h
|
|
Vibration
|
ΔR≤±(1%R+0.05Ω)
|
10~500Hz,
0.75mm
,3h
|
|
Solderability
|
Terminal
is well covered with solder and the solder can
freely flow
|
235±
5℃
2±0.1s
|
|
Thermal
cycle
|
ΔR≤±(3%R+0.05Ω)
|
-55℃
/
275℃
3 cycles
|
|
Low
atmospheric pressure
|
No
breakdown or flashover
|
5W:65V
10W:100V
20(25)W:200V
50W:400V
Way of V-shaped block
|
|
Surface
temperature rise
|
≤
275℃
|
VR
|
|
Short-time
load
|
ΔR≤±(3%R+0.05Ω)
|
Room
temperature,VR
100h
|
|
|
Specification
are subject to change without notice.
|