Stability reaches 5%
|
| ■
Wide resistance range, high accuracy
|
|
RXJ1 Precision Wire Wound Resistor
|
|
|
★ Standard
▲
Q/RU163-1999 Type RXJ1 precision wire-wound
resistor specification
★Dimension
(mm)
|

|
|
Type
|
Power
|
Dimension
max
|
|
L
|
D
|
d
|
H
|
h
|
|
RXJ1
|
0.5
|
16
|
16
|
3.7
|
23.5
|
13
|
|
1
|
23.5
|
16.5
|
4.7
|
23.5
|
13
|
|
2
|
33.5
|
20
|
4.7
|
26
|
13
|
|
|

|
|
|
★ Main specification
|
|
Type
|
Rated
power at
85℃
(W)
|
Resistance
range
(Ω)
|
Resistance
tolerance
±(%)
|
Operating
voltage max.
(V)
|
|
RXJ1
|
0.5
|
1~150K
|
<100Ω
1(F)
≥100Ω
0.5(D)1(F)
|
400
|
|
1
|
1~300K
|
400
|
|
2
|
20~
1M
|
450
|
|
|
★ Main inspection items, methods &
requirements
|
|
Items
|
Requirements
|
Methods
|
|
Torque
|
No
mechanical damage on framework, exit
is not loose
|
25N·cm
|
|
Soldering
|
Easy
to welding,No
mechanical damage
|
Electric
soldering iron (100W)≤5S
|
|
Low
atmospheric pressure
|
No breakdown or flashover
|
0.67Kpa,200V 1min
|
|
Temperature
rise
|
≤
125℃
|
VR
30min
|
|
Moisture
|
ΔR≤±0.2%R
|
40℃
,(95~98)% 48h
|
|
Thermal
cycle
|
ΔR≤±0.2%R
|
-55℃
~+
85℃
3
cycles
|
|
Vibration
|
ΔR≤±0.2%R
|
(20~200)Hz;
40m
/s2
|
|
Shock
|
ΔR≤±0.2%R
|
100m
/s2
10000
times
|
|
Centrifugation
|
ΔR≤±0.2%R
|
200m
/s2
|
|
|
Specification are subject